Liner Systems

Fall protection and non-fall protection available, used in roof applications

On This Page:

Liner Systems for Metal Buildings

Non-Fall Protection Liner Systems

Provide a clean, finished appearance and can obtain higher R-values for metal building roof insulation applications

Read More

Fall Protection Arrest Systems

Increased productivity and fall protection on large metal building roof insulation projects

Read More

What


You Need.


When


You Need It.


Start Online Quote

Call Your Local Branch

Find Local Branch

The Brands You Trust

Thermal Design Logo - Innovative Energy Saving Products
Owens Corning Brand Logo

How to Use Metal Building Insulation Liner Systems

Metal building insulation liner systems are made specifically for each building and its bay configurations. They are most commonly used in metal building and post frame building roof insulation projects, and Service Partners carries metal building insulation liner systems with fall protection and without fall protection.

Metal Building Insulation Liner System R-Values

When you’re looking for metal building insulation liner systems, you’ll find a wide range of R-values available, including R-10, 11, 13, 16, 19, 25, 30 and multiples thereof, up to R-49. (R-value requirements are governed by the Authority Having Jurisdiction (AHJ) in each state or municipality. Please check with your AHJ to determine the correct code for your area.)

Different regions require different levels of insulation.This map shows the most cost-effective levels of insulation for the different climate zones in the U.S. Based on your zone, use the table to find out how much insulation you need. The higher the R-value of insulation, the more thermal insulating capacity it has. Zones 1, 2, and 3 make up the southern portions of the U.S. and have an average suggested minimum insulation rating of R-30 in attics and R-13 along floors. Zones 4 to 7, which cover the northern half of the country, suggest that attic insulation have a minimum R-38 rating and floor insulation have a minimum R-25 rating.

Contact Your Local Branch

Call Your Local Branch

Find Local Branch

Common Accessories

Patch Tape

To patch tears in the facing and seal around openings

Learn More

Banding

For insulation support in the puril cavity

Learn More

About Metal Building Insulation Liner Systems

A metal building insulation liner system is a high R-value fabric liner system that utilizes the full depth of the purlin cavity.

What Are Metal Building Insulation Liner Systems?

A metal building insulation liner system is a high R-value fabric liner system that utilizes the full depth of the purlin cavity. The first layer of unfaced insulation is installed between and parallel to the purlins. The second, unfaced layer of fiberglass is installed above and perpendicular to the purlins, from eave to eave. It is supported by a heavy duty fabric lined vapor barrier, which is attached to the bottom of the purlins. Metal building insulation liner systems are available with fall protection and without fall protection benefits.

We Carry the Metal Building Insulation Liner System Brands You Want

Service Partners has a large selection of metal building insulation liner systems to meet your needs. We have a wide variety of liner systems from trusted, industry-leading brands like Thermal Design, Diamond Nets, and Owens Corning. Whether you’re interested in the Simple Saver family of liner systems, the Owens Corning ELAMINATOR System, or something else, we can help you find what you need. Call today!

Metal Building Insulation Liner System Supplies Near You

Service Partners has a local branch to help you find the metal building insulation liner system to fit your needs, no matter where you are located or what project you’re working on. Our internal specialists will help you with liner training and placement, as well as finding the right product for your needs. Get in touch with our team today!

Metal Building Insulation Liner System Benefits

Metal building insulation liner systems provide a number of benefits to metal building projects, including achieving high R-values, a continuous vapor barrier, and an aesthetically pleasing appearance.

Achieve High R-Values

When it comes to metal building roof insulation projects, high R-values are often necessary to achieve, which can be done with the help of many metal building insulation liner systems. To find the right metal building insulation liner system to fit your R-value and climate’s needs, contact your local Service Partners team today!

Continuous Vapor Barrier

Metal building insulation liner systems are great for providing a continuous vapor barrier, which can also act as fall protection in some liner systems. Both fall protection and non-fall protection liner systems can achieve high vapor barrier performance. Browse through our catalog to find out which liner system will fit your vapor barrier requirements.

Aesthetically Pleasing Appearance

Certain types of metal building insulation liner systems, such as the Simple Saver family and non-fall protection liner systems, provide an aesthetically pleasing appearance, as they cover the purlins. Whether this is requested by the building owner or not, you can find a metal building insulation liner system that creates a clean, finished appearance to fit your needs.

Common Metal Building Insulation Liner System Questions

When you have questions about metal building insulation liner systems, we have answers. Check out common questions below and contact us if you don’t see your question listed.

Where in a Building or Home Are Metal Building Insulation Liner Systems Normally Used?

Metal building insulation liner systems are most commonly seen utilized for insulation on metal building roofs, but some systems can also be used in post frame buildings. A metal building insulation liner system is custom-made, specifically for each building and its bay configurations, and they are typically used in commercial and industrial construction.

What Are the R-Values for Metal Building Insulation Liner Systems?

Metal building insulation liner systems are available in a wide range of R-values to fit your needs. You can typically find metal building insulation liner systems in R-values of R-10, 11, 13, 16, 19, 25, 30 and multiples thereof, up to R-49. If you need help choosing the right R-value for your project, get in touch with our team today.

In What Geographies Can Metal Building Insulation Liner Systems Be Used?

No matter where your metal building or post frame roof insulation project is located, you can utilize one of the top-performing metal building insulation liner systems found through your local Service Partners branch. Our team can help you find the right metal building insulation liner system for your needs – contact us today!

Can Metal Building Insulation Liner Systems Be Used in Residential or Commercial Construction?

When it comes to metal building insulation liner systems, you’ll typically find them being utilized in commercial or industrial construction, but not for residential construction. They are most commonly used to achieve high R-values, increase productivity, and provide an aesthetically pleasing appearance in commercial or industrial metal building roof insulation projects.

The Service Partners Difference

Built for Contractors

Residential and commercial contractors trust our service and reliability

Get All Your Building Supplies

Choose from one of the largest selections of building products in the nation

National Distribution

We are the leading insulation distributor in the U.S., ready to serve with 75+ branches nationwide

Next Day Delivery and Service Available

Get the supplies you need to move your project forward on time

Ready To Place An Order?

Contact Service Partners for all of your building supply needs.

Start Online Quote
Call Your Local Branch
Find Local Branch